Review




Structured Review

Compex Inc stimulation pen compex
Stimulation Pen Compex, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/stimulation pen compex/product/Compex Inc
Average 90 stars, based on 1 article reviews
stimulation pen compex - by Bioz Stars, 2026-04
90/100 stars

Images



Similar Products

90
Compex Inc stimulation pen compex
Stimulation Pen Compex, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/stimulation pen compex/product/Compex Inc
Average 90 stars, based on 1 article reviews
stimulation pen compex - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Compex Inc stimulation pen
Experimental protocol. The different <t>stimulation</t> frequencies and pulse durations are displayed in the ascending order but were in fact randomized. MVC = maximal voluntary contraction; NMES = neuromuscular electrical stimulation.
Stimulation Pen, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/stimulation pen/product/Compex Inc
Average 90 stars, based on 1 article reviews
stimulation pen - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Serono recombinant human follicle-stimulating hormone (hfsh) gonal-f pen
Timeline of experimental procedures by date. (A) Schedule of superovulated recipients. (B) Schedule of synchronized recipients. GnRH-a, gonadotrophin-releasing hormone antagonist; hCG, human chorionic gonadotrophin; <t>hFSH,</t> <t>human</t> <t>follicle-stimulating</t> hormone; hMG, human menopausal gonadotrophin.
Recombinant Human Follicle Stimulating Hormone (Hfsh) Gonal F Pen, supplied by Serono, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/recombinant human follicle-stimulating hormone (hfsh) gonal-f pen/product/Serono
Average 90 stars, based on 1 article reviews
recombinant human follicle-stimulating hormone (hfsh) gonal-f pen - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Compex Inc stimulation pen motor point pen
Timeline of experimental procedures by date. (A) Schedule of superovulated recipients. (B) Schedule of synchronized recipients. GnRH-a, gonadotrophin-releasing hormone antagonist; hCG, human chorionic gonadotrophin; <t>hFSH,</t> <t>human</t> <t>follicle-stimulating</t> hormone; hMG, human menopausal gonadotrophin.
Stimulation Pen Motor Point Pen, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/stimulation pen motor point pen/product/Compex Inc
Average 90 stars, based on 1 article reviews
stimulation pen motor point pen - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

86
World Precision Instruments pen type stimulation electrode

Pen Type Stimulation Electrode, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pen type stimulation electrode/product/World Precision Instruments
Average 86 stars, based on 1 article reviews
pen type stimulation electrode - by Bioz Stars, 2026-04
86/100 stars
  Buy from Supplier

93
ADInstruments pen type stimulation electrode

Pen Type Stimulation Electrode, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pen type stimulation electrode/product/ADInstruments
Average 93 stars, based on 1 article reviews
pen type stimulation electrode - by Bioz Stars, 2026-04
93/100 stars
  Buy from Supplier

90
Compex Inc motor point stimulation pen motor point pen

Motor Point Stimulation Pen Motor Point Pen, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/motor point stimulation pen motor point pen/product/Compex Inc
Average 90 stars, based on 1 article reviews
motor point stimulation pen motor point pen - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Compex Inc mp pen stimulator comex performance muscle stimulator kit 6

Mp Pen Stimulator Comex Performance Muscle Stimulator Kit 6, supplied by Compex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mp pen stimulator comex performance muscle stimulator kit 6/product/Compex Inc
Average 90 stars, based on 1 article reviews
mp pen stimulator comex performance muscle stimulator kit 6 - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


Experimental protocol. The different stimulation frequencies and pulse durations are displayed in the ascending order but were in fact randomized. MVC = maximal voluntary contraction; NMES = neuromuscular electrical stimulation.

Journal: Scientific Reports

Article Title: Centrally mediated responses to NMES are influenced by muscle group and stimulation parameters

doi: 10.1038/s41598-024-75145-2

Figure Lengend Snippet: Experimental protocol. The different stimulation frequencies and pulse durations are displayed in the ascending order but were in fact randomized. MVC = maximal voluntary contraction; NMES = neuromuscular electrical stimulation.

Article Snippet: Then, single stimuli (monophasic pulses of 1 ms at 400 V) were delivered using a stimulation pen (Compex, Ecublens, Switzerland) to precisely localize the motor points of the different muscles, i.e. the site where the strongest response was induced by the weakest current .

Techniques:

Position of the participant and placement of the stimulation and electromyographic (EMG) electrodes on each muscle group (elbow flexors, knee extensors, plantar flexors from left to right). Arrows represent the direction of force production.

Journal: Scientific Reports

Article Title: Centrally mediated responses to NMES are influenced by muscle group and stimulation parameters

doi: 10.1038/s41598-024-75145-2

Figure Lengend Snippet: Position of the participant and placement of the stimulation and electromyographic (EMG) electrodes on each muscle group (elbow flexors, knee extensors, plantar flexors from left to right). Arrows represent the direction of force production.

Article Snippet: Then, single stimuli (monophasic pulses of 1 ms at 400 V) were delivered using a stimulation pen (Compex, Ecublens, Switzerland) to precisely localize the motor points of the different muscles, i.e. the site where the strongest response was induced by the weakest current .

Techniques:

A Original traces of evoked force from a representative subject for plantar flexors (PF, upper panels), knee extensors (KE, middle panels) and elbow flexors (EF, lower panels). Force traces are presented for each pulse duration and frequency condition. B Original traces of sustained electromyographic (EMG) from a representative subject for the soleus (left), vastus lateralis (middle) and biceps brachii (right). EMG traces are presented for each pulse duration and frequency condition. Stimulation artifacts always precede sustained EMG activity, when visible.

Journal: Scientific Reports

Article Title: Centrally mediated responses to NMES are influenced by muscle group and stimulation parameters

doi: 10.1038/s41598-024-75145-2

Figure Lengend Snippet: A Original traces of evoked force from a representative subject for plantar flexors (PF, upper panels), knee extensors (KE, middle panels) and elbow flexors (EF, lower panels). Force traces are presented for each pulse duration and frequency condition. B Original traces of sustained electromyographic (EMG) from a representative subject for the soleus (left), vastus lateralis (middle) and biceps brachii (right). EMG traces are presented for each pulse duration and frequency condition. Stimulation artifacts always precede sustained EMG activity, when visible.

Article Snippet: Then, single stimuli (monophasic pulses of 1 ms at 400 V) were delivered using a stimulation pen (Compex, Ecublens, Switzerland) to precisely localize the motor points of the different muscles, i.e. the site where the strongest response was induced by the weakest current .

Techniques: Activity Assay

Comparison of extra force ( A ) and sustained electromyographic (EMG) activity ( B ) between muscle groups (PF: plantar flexors; KE: knee extensors; EF: elbow flexors) at each stimulation frequency. Individual and mean data (red) are displayed. For extra force, positive values representing responders are in black while negative values corresponding to non-responders are in grey. EMG activity was measured on soleus for plantar flexors, vastus lateralis for knee extensors and biceps brachii for elbow flexors. * p < 0.05, ** p < 0.01, *** p < 0.001.

Journal: Scientific Reports

Article Title: Centrally mediated responses to NMES are influenced by muscle group and stimulation parameters

doi: 10.1038/s41598-024-75145-2

Figure Lengend Snippet: Comparison of extra force ( A ) and sustained electromyographic (EMG) activity ( B ) between muscle groups (PF: plantar flexors; KE: knee extensors; EF: elbow flexors) at each stimulation frequency. Individual and mean data (red) are displayed. For extra force, positive values representing responders are in black while negative values corresponding to non-responders are in grey. EMG activity was measured on soleus for plantar flexors, vastus lateralis for knee extensors and biceps brachii for elbow flexors. * p < 0.05, ** p < 0.01, *** p < 0.001.

Article Snippet: Then, single stimuli (monophasic pulses of 1 ms at 400 V) were delivered using a stimulation pen (Compex, Ecublens, Switzerland) to precisely localize the motor points of the different muscles, i.e. the site where the strongest response was induced by the weakest current .

Techniques: Comparison, Activity Assay

Effect of  stimulation  frequency on extra force and sustained EMG activity by muscle group.

Journal: Scientific Reports

Article Title: Centrally mediated responses to NMES are influenced by muscle group and stimulation parameters

doi: 10.1038/s41598-024-75145-2

Figure Lengend Snippet: Effect of stimulation frequency on extra force and sustained EMG activity by muscle group.

Article Snippet: Then, single stimuli (monophasic pulses of 1 ms at 400 V) were delivered using a stimulation pen (Compex, Ecublens, Switzerland) to precisely localize the motor points of the different muscles, i.e. the site where the strongest response was induced by the weakest current .

Techniques: Activity Assay

Timeline of experimental procedures by date. (A) Schedule of superovulated recipients. (B) Schedule of synchronized recipients. GnRH-a, gonadotrophin-releasing hormone antagonist; hCG, human chorionic gonadotrophin; hFSH, human follicle-stimulating hormone; hMG, human menopausal gonadotrophin.

Journal: Frontiers in Veterinary Science

Article Title: Comparative analysis of superovulated versus uterine-embryo synchronized recipients for embryo transfer in cynomolgus monkeys ( Macaca fascicularis )

doi: 10.3389/fvets.2024.1452631

Figure Lengend Snippet: Timeline of experimental procedures by date. (A) Schedule of superovulated recipients. (B) Schedule of synchronized recipients. GnRH-a, gonadotrophin-releasing hormone antagonist; hCG, human chorionic gonadotrophin; hFSH, human follicle-stimulating hormone; hMG, human menopausal gonadotrophin.

Article Snippet: The regimen included the administration of a gonadotropin-releasing hormone (GnRH) antagonist, ganirelix (Orgalutran Inj, ORGANON, Seoul, Korea), at a dosage of 0.125 mg once daily, and recombinant human follicle-stimulating hormone (hFSH) (Gonal-F Pen, Merck, Serono, Italy) at 37.5 IU twice daily intramuscularly on days 1–6.

Techniques:

Journal: STAR Protocols

Article Title: Calcium measurements in enzymatically dissociated or mechanically microdissected mouse primary skeletal muscle fibers

doi: 10.1016/j.xpro.2023.102260

Figure Lengend Snippet:

Article Snippet: CRITICAL: We use a pen-type stimulation electrode connected to a generic current pulse stimulator with up to 100V stimulation voltage (World Precision Instruments; model no. SYS-A300 or Aurora Scientific; model no. 701C).

Techniques: Recombinant, Membrane, Fluorescence, Dissection

Journal: STAR Protocols

Article Title: Calcium measurements in enzymatically dissociated or mechanically microdissected mouse primary skeletal muscle fibers

doi: 10.1016/j.xpro.2023.102260

Figure Lengend Snippet:

Article Snippet: Pen-type stimulation electrode , ADInstruments , MLA0320.

Techniques: Recombinant, Membrane, Fluorescence, Dissection